Supply and Installation of a PEM Electrolyser Test System

A Tender Notice
by UNIVERSITY OF BIRMINGHAM

Source
Find a Tender
Type
Contract (Goods)
Duration
11 month
Value
£326K
Sector
INDUSTRIAL
Published
22 Dec 2021
Delivery
28 Feb 2022 to 31 Jan 2023
Deadline
26 Jan 2022 12:00

Concepts

Location

West Midlands England:

Geochart for 1 buyers and 0 suppliers

1 buyer

Description

The University of Birmingham invites tenders for supply of a PEM electrolyser test system. The system will be used to test membrane electrode assemblies with an active area up to 50 cm2 to optimise their fabrication process based on a granted project. A cathode operating pressure of 3.5 MPa or higher is required with the maximum current no less than 125 A. The test system also needs to be able to conduct both electrochemical impedance spectroscopy and cyclic voltammetry analysis, as well as including a H2 concentration sensor at the air side to monitor the hydrogen penetration rate and safety. Also, this system should incorporate a water supply system, and the PC with the control software for conducting the required operation. This project may be funded by the European Regional Development Fund (ERDF) or European Structural and Investment Fund (ESIF) or Research Councils UK (RCUK), the strategic partnership of the UK's seven Research Councils.

Total Quantity or Scope

The system will be used to test membrane electrode assemblies to optimise their fabrication process based on a granted project. The specification requirements are as below Specification i. PEM test station including Electronic power supply for the electrolyser with a voltage range of 5 V or higher, and current of 125 A or higher. Automatic back pressure control module, up to 35 bar or higher. Fully automated and unattended operation. 2 separate electrolyte loops with circulation pumps for the anode and cathode with a temperature range up to 80o C or higher. Gas/liquid separation. Real PLC for safe test stand operation. Continuous data acquisition (flight recorder). Control PC with the operating software. PID loops for cell end plate heaters with temperature sensor. H2 concentration sensor at the air side with a measurement range of 0 - 5 Vol% H2 in O2. iii. Integrated DI-water supply system from storage tank. iv. Impedance analyzer with a frequency range of 1 mHz to 15 kHz or larger, an excitation current of ±10-30A or higher, and DC Voltage input of 10-20 V or higher. v. Cyclic voltammetry add-on with additional H2 input line with MFC on cathode side. vi. Electrolyser Cell Hardware of 25 or 50 cm2 for operating pressure up to 35 bar or higher. vii. Optional component technologies 1 External DI-water supply system. 2 Flow meter for anode or cathode electrolyte recirculation circuit. 3 Hydrogen and oxygen flow measurement. 4 O2 concentration sensor in hydrogen side.

Award Criteria

Compliance to the Specifications 40
After Sales and Technical back up 10
Delivery and Training 10
Sustainability and Environmental 5
Standard Supplier Questionnaire (SQ) 10
price 25

CPV Codes

  • 38000000 - Laboratory, optical and precision equipments (excl. glasses)

Indicators

  • This is a one-off contract (no recurrence)
  • Renewals are not available.

Other Information

** PREVIEW NOTICE, please check Find a Tender for full details. **

Reference

Domains