A system for non-invasive preclinical ultrasound imaging

A Contract Award Notice
by UNIVERSITY OF READING

Source
Find a Tender
Type
Contract (Goods)
Duration
not specified
Value
€368K
Sector
INDUSTRIAL
Published
11 Oct 2022
Delivery
not specified
Deadline
n/a

Concepts

Location

South East England: University of Reading Whiteknights Campus Reading

Geochart for 1 buyers and 1 suppliers

1 buyer

1 supplier

Description

For the purchase of a system for non-invasive preclinical ultrasound imaging. A single system is to be purchased that will permit visualisation of all of the following preclinical models: • Mouse embryos and zebrafish at resolutions down to 30 µm using an ultra-high frequency transducer (up to 71 MHz). • Mouse hearts and the vasculature in genetic and drug-induced models of disease at 30 µm resolution using a transducer of 30-40 MHz with a frame rate capable of imaging heart rates of up to 750 beats per minute. ECG-gating is also required for 3D reconstruction of the heart. • Rat hearts and the vasculature in genetic and drug-induced models of disease (as detailed above for mice) using a transducer of ~29 MHz. • Mouse or rat brains (requiring a lower frequency transducer of ~22 MHz). Additional capability is required for upgrading for imaging of pig hearts and the vasculature (requires low frequency transducers of 4-10 MHz) and for photoacoustic imaging. The system must have the following provision: • Integrated physiology traces for small animals, including display of ECG, respiration waveform, and body temperature. • Capability for capturing B-mode and M-mode images, and for analysis of the images to provide data on cardiac and vascular function and dimensions in the above preclinical models (including strain and speckle-tracking). • Capability for Power Doppler, Pulsed-Wave Doppler, Pulsed-Wave tissue Doppler and colour Doppler for assessment of blood flow. • Capability for contrast imaging. The University has published this VEAT notice and intends to award a contract to FUJIFILM Visualsonics Inc. following the expiry of 10 full calendar days after the expiry of this notice.

Award Detail

1 Fujifilm Visualsonics (None)
  • A system for non-invasive preclinical ultrasound imaging
  • Reference: 028507-2022-uor-lab-23-002-1
  • Value: £368,500

CPV Codes

  • 38400000 - Instruments for checking physical characteristics
  • 38000000 - Laboratory, optical and precision equipments (excl. glasses)

Other Information

** PREVIEW NOTICE, please check Find a Tender for full details. **

Reference

Domains