Exhaust and Inflame Gas Analyser (3 Lots)

A Contract Award Notice
by UNIVERSITY OF SHEFFIELD

Source
Find a Tender
Type
Contract (Goods)
Duration
not specified
Value
£130K
Sector
INDUSTRIAL
Published
09 Jan 2023
Delivery
not specified
Deadline
n/a

Concepts

Location

University of Sheffield, Sustainable Aviation Fuels - Innovation Centre, Sheffield Business Park, Europa Avenue, Sheffield S9 1ZA

Geochart for 1 buyers and 1 suppliers

1 buyer

1 supplier

Description

To support overall fundamental and applied research activity, proposals are requested for a gas analysis system for exhaust and inflame gas composition measurements to be utilised across all combustion facilities on site as well as potentially other offsite facilities. This requirement is divided into 3 individual Lots. ● LOT 1: Focuses on standard combustion gases and inflame measurements ● LOT 2: Covers additional requirements for hydrogen and methane analysis for process gas ● LOT 3: Covers ultra low level (ppb) trace gas analysis of sulphur compounds in natural gas, CO2 stream or flue gas

Lot Division

1

The tender is divided into separate Lots: ● LOT 1: Focuses on standard combustion gases and inflame measurements (ideally including space for additional analyser under Lot 2 and Lot 3). The system needs to be able to measure gases according to 'Table 2.1 - LOT 1 gas analysers required' ● LOT 2: Covers additional requirements for hydrogen and methane analysis for process gas monitoring (as a standalone analyser or integrated into LOT 1). With gas concentration encountered summarised in "Table 2.2. Approximate gas compositions encountered on site (typically values/upper ranges)" in the light blue boxes. ● LOT 3: Covers ultra low level (ppb) trace gas analysis of sulphur compounds in natural gas, CO2 stream or flue gas, to include at the lowest range approximately 0-50ppb (as a standalone analyser or integrated into LOT 1 or LOT 2). The purpose of this analyser is process monitoring of MCFC feed gas quality. The species of interests include SO2 (essential requirement), and it is an advantage if it can also measure other sulphur containing compounds such as: H2S, COS, CS2. With gas concentration encountered summarised in "Table 2.2. Approximate gas compositions encountered on site (typically values/upper ranges)" in the light blue boxes

2

The tender is divided into separate Lots: ● LOT 1: Focuses on standard combustion gases and inflame measurements (ideally including space for additional analyser under Lot 2 and Lot 3). The system needs to be able to measure gases according to 'Table 2.1 - LOT 1 gas analysers required' ● LOT 2: Covers additional requirements for hydrogen and methane analysis for process gas monitoring (as a standalone analyser or integrated into LOT 1). With gas concentration encountered summarised in "Table 2.2. Approximate gas compositions encountered on site (typically values/upper ranges)" in the light blue boxes. ● LOT 3: Covers ultra low level (ppb) trace gas analysis of sulphur compounds in natural gas, CO2 stream or flue gas, to include at the lowest range approximately 0-50ppb (as a standalone analyser or integrated into LOT 1 or LOT 2). The purpose of this analyser is process monitoring of MCFC feed gas quality. The species of interests include SO2 (essential requirement), and it is an advantage if it can also measure other sulphur containing compounds such as: H2S, COS, CS2. With gas concentration encountered summarised in "Table 2.2. Approximate gas compositions encountered on site (typically values/upper ranges)" in the light blue boxes.

3

The tender is divided into separate Lots: ● LOT 1: Focuses on standard combustion gases and inflame measurements (ideally including space for additional analyser under Lot 2 and Lot 3). The system needs to be able to measure gases according to 'Table 2.1 - LOT 1 gas analysers required' ● LOT 2: Covers additional requirements for hydrogen and methane analysis for process gas monitoring (as a standalone analyser or integrated into LOT 1). With gas concentration encountered summarised in "Table 2.2. Approximate gas compositions encountered on site (typically values/upper ranges)" in the light blue boxes. ● LOT 3: Covers ultra low level (ppb) trace gas analysis of sulphur compounds in natural gas, CO2 stream or flue gas, to include at the lowest range approximately 0-50ppb (as a standalone analyser or integrated into LOT 1 or LOT 2). The purpose of this analyser is process monitoring of MCFC feed gas quality. The species of interests include SO2 (essential requirement), and it is an advantage if it can also measure other sulphur containing compounds such as: H2S, COS, CS2. With gas concentration encountered summarised in "Table 2.2. Approximate gas compositions encountered on site (typically values/upper ranges)" in the light blue boxes.

Award Detail

1 Bohr (None)
  • Reference: 000501-2023-3461/dm-1
  • Value: £130,396

Renewal Options

As described within the tender documents

Award Criteria

Various 70
price 30

CPV Codes

  • 38434000 - Analysers
  • 38000000 - Laboratory, optical and precision equipments (excl. glasses)
  • 38430000 - Detection and analysis apparatus

Indicators

  • Options are available.

Other Information

** PREVIEW NOTICE, please check Find a Tender for full details. ** Lots 2 and 3 have not been awarded. Only one response was received in total & unfortunately the offer received for these 2 lots were not deemed suitable.

Reference

Domains