Concrete Testing of R1 Bioshield

A Contract Award Notice
by NUCLEAR RESTORATION SERVICES LIMITED

Source
Find a Tender
Type
Contract ()
Duration
not specified
Value
£30K
Sector
MISCELLANEOUS
Published
21 Aug 2025
Delivery
not specified
Deadline
n/a

Concepts

Location

Geochart for 1 buyers and 1 suppliers

1 buyer

1 supplier

Description

tests conducted will be as follows: - Hammer Tap survey and Visual Inspection - In each location, two areas shall be selected – one vertical bar and one transverse bar, for intrusive work to expose reinforcement bar. In each case, the bar is to be located using nondestructive means and the concrete is to be carefully broken away to expose the bar. Once opened, measurements of the steel reinforcement will be taken as well as the general condition of the steel and type of bar recorded. - Chloride Testing - Cover Meter Testing - Core Sampling and Petrographic Analysis - Carbonation Testing - Half-Cell Potential Testing - Linear Polarisation Resistance

Award Detail

1 Corrosion Engineering Solutions (Hertfordshire)
  • Concrete Testing of R1 Bioshield
  • Reference: 1
  • Value: £29,850